165 Heineberg Drive,
Colchester, VT


MODEL PTE-1 CLASS 2 CONTAINMENT SYSTEM
ENCLOSED FILL STATION SINGLE CYLINDER FILL ENCLOSURE, 5000 PSI

The PTE-1 Cylinder Fill Enclosure fills one cylinder at a time. This explosion proof enclosure provides increased safety, only operating when the door is closed. Designed to contain the destructive force of accidental cylinder rupture or hose failure, While allowing the air blast to be vented quickly and in a direction away from the operator. (Reference CGA pamphlet G-7-1989 Compressed Air for Human Respiration Section 7)

THIS FILL STATION CONSISTS OF:

A safety interlock prevents SCBA or SCUBA filling unless the front access door is completely closed and locked in place. The carriage design “tilts” toward the operator whenever the door is opened. This facilitates loading and unloading cylinders and minimizes operator fatigue. Teflon slides protect cylinder from scuffing.

The fill hose is designed for easy connection inside the enclosure.

OPTIONS:
Wall Mounted Control Panel Includes:

  • 1 Input Pressure Gauge 0-7500 PSI
  • 1 High Pressure Adjustable Regulator 0-5000 PSI
  • 1 Output Pressure Gauge 0-6000 PSI
  • 1 Fill Valve
  • 1 Compressor Valve
  • 1 Cascade Valve
  • 1 Fully Labeled Panel

DIMENSIONS:

Fill Station: Width 21”, Height 42Ό”, Depth 26”, Weight: 300#

Optional Panel: Width 26”
, Height 21”, Depth 4”

NFPA 1901 23-9.4.1 CERTIFIED BY AN INDEPENDENT FACILITY


double fill
MODEL PTE-2 CLASS 2 CONTAINMENT SYSTEM
ENCLOSED FILL STATION DOUBLE CYLINDER FILL ENCLOSURE, 5000 PSI

The PTE-2 Cylinder Fill Enclosure fills up to two cylinders at once. This explosion proof enclosure provides increased safety, only operating when the door is closed. Designed to contain the destructive force of accidental cylinder rupture or hose failure, While allowing the air blast to be vented quickly and in a direction away from the operator. (Reference CGA pamphlet G-7-1989 Compressed Air for Human Respiration Section 7)

THIS FILL STATION CONSISTS OF:

A safety interlock prevents SCBA or SCUBA filling unless the front access door is completely closed and locked in place. The carriage design “tilts” toward the operator whenever the door is opened. This facilitates loading and unloading cylinders and minimizes operator fatigue. Teflon slides protect cylinder from scuffing.

The fill hoses are designed for easy connection inside the enclosure.

OPTIONS:
Wall Mounted Control Panel Includes:
1 Input Pressure Gauge 0-7500 PSI
1 High Pressure Adjustable Regulator 0-5000 PSI
1 Output Pressure Gauge 0-6000 PSI
2 Fill Valves
1 Compressor Valve
1 Cascade Valve
Fully Labeled Panel

DIMENSIONS:

Fill Station: Width 30”, Height 42Ό”, Depth 26”, Weight: 400#

Optional Panel: Width 26”
, Height 21”, Depth 4”

NFPA 1901 23-9.4.1 CERTIFIED BY AN INDEPENDENT FACILITY

Poseidon Air Systems also makes fill panels to fit any of your high pressure air needs.
OXYGEN-CLEAN CLASS II CONTAINMENT SYSTEMS

HPE4500-1

HPE4500-2

ONE OR TWO CYLINDER FILL ENCLOSURES 5,000 PSI

The HPE4500-1 cylinder fill enclosure will fill 1 cylinder at a time. The HPE4500-2 cylinder fill enclosure will fill 2 cylinders at a time. These enclosures provide increased safety during the filling process, only operating when their doors are closed and locked. (Reference CGA pamphlet G-7-1989, Compressed Air for Human Respiration, Section 7 and NFPA 1901-71, 1999 Edition, 23.9 thru 23.9.4.2). .

These units feature 1/2” thick steel doors with safety interlocks and a 1/4” steel tilting cylinder holders, which makes loading and unloading easy. Teflon slides on the steel cylinder holders protect cylinders from scuffing. Fill hoses are designed for easy connection and inside the enclosures for increased safety.

A safety interlock prevents filling unless the front access door is completely closed and locked in place. All control components are located inside the compartment.

The carriage design ‘tilts’ towards the operator whenever the doors are opened. This facilitates loading and unloading cylinders and minimizes operator fatigue.

Standard Features:

All parts, fittings & fill components are Oxygen-Clean

  • 1 Door locking bar 1/2” thick, (manual)
  • 1 Bulkhead fitting connection from the cascade system
  • Panel-mount valves on the HPE4500-2
  • Oxygen-Clean fill hoses complete with stainless bleed value & fill adaptor. Designed to contain the destructive force of accidental cylinder rupture or hose failure, while allowing the blast to be vented quickly and in a direction away from the operator.


The construction of these units consist of an inner drawer of 1/4” steel plate on 4 sides with an additional 1/4” plate door to provide 1/2” protection at the front. The outer cabinet is 1/4” steel plate on four sides, this gives 1/2” steel protection on all four sides. Allowing the most protection available in a single cylinder containment.

Call or e-mail for more information or price quote.
165 Heineberg Drive, Colchester, Vermont 05446
Telephone: 802-862-0051, Fax: 802-865-0400,
Toll Free: 800-848-4829
e-mail: poseidonair@aol.com
Hours: Monday - Friday 8 am- 4:30 pm

Home Page